Indexado em
  • Banco de Dados de Periódicos Acadêmicos
  • Abra o Portão J
  • Genamics JournalSeek
  • Chaves Acadêmicas
  • JournalTOCs
  • Infraestrutura Nacional de Conhecimento da China (CNKI)
  • CiteFactor
  • Scimago
  • Diretório de Periódicos de Ulrich
  • Biblioteca de periódicos eletrônicos
  • RefSeek
  • Universidade de Hamdard
  • EBSCO AZ
  • OCLC- WorldCat
  • Catálogo online SWB
  • Biblioteca Virtual de Biologia (vifabio)
  • publons
  • MIAR
  • Comissão de Bolsas Universitárias
  • Fundação de Genebra para Educação e Pesquisa Médica
  • Euro Pub
  • Google Scholar
Compartilhe esta página
Folheto de jornal
Flyer image

Abstrato

Bioavailability of Two Oral-Granule Formulations of a Single Dose of 4-Mg Oral Granules of Montelukast: A Randomized, Two-Period Crossover Comparison in Healthy Mexican Adult Volunteers

Gabriel Mendoza-Tamayo, Alejandra Rosete-Reyes, Jessica González-Bañuelos, Ericka López-Bojórquez, Victoria Burke-Fraga and Mario González-de la Parra

Montelukast is a leukotriene receptor antagonist. In Mexico, the oral granules at the dose of 4 mg are indicated for children aged 6 months to 5 years for the treatment of asthma and/or allergic rhinitis. The aim of this study was to compare the bioavailability and to determine the bioequivalence of a test formulation (oral granules) containing 4 mg of montelukast, with its corresponding reference drug formulation, and to generate data regarding the oral bioavailability of this drug in the Mexican population. This single-dose, randomized-sequence, single-blind, twoperiod crossover study under fasting conditions was conducted on a total of 26 healthy Mexican adult subjects of both genders , with a seven-day washout period. Study formulations were administered after a 10-hour overnight fast. For pharmacokinetic analysis, blood samples were drawn at 0 (baseline), 0.25, 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 10, 12 and 24 hours after administration. Plasma concentrations of montelukast were determined using HPLC coupled to a mass spectrometry (MS/MS) detector. The test and reference formulations were considered bioequivalent if the 90% CIs for the geometric mean test/reference ratios were within a predetermined range of 80% to 125%. The 90% CIs for montelukast Cmax, AUC0–t and AUC0–∞ were 97.57% to 109.35%, 101.81% to 108.92%, and 101.55% to 109.96%, respectively. In this study a single dose of the test formulation met the regulatory requirements for assuming bioequivalence, based on the rate and extent of absorption.

Isenção de responsabilidade: Este resumo foi traduzido usando ferramentas de inteligência artificial e ainda não foi revisado ou verificado